Please look forward to the upgrade of the website, thank you!

Inkbird

Programmable CO2 Temperature Controller ICC-500T

Key Points:

【Double Outlets】Pls plug CO₂ regulator or generator into WORK1, exhaust fan into WORK2.
【Programmable】Controls the CO2(ppm) within the desired range and supports calibration and alarms
【Plug-n-play】The CO2 controller will turn on/off the device when reaches the desired CO2(ppm) level.
【Digital Display】Both the measured CO2 and the desired CO2 are (ppm)displayed on the CO2 Controller
Reliable】CE&FCC certificated. S01 Sensor is suitable for home growing and HVAC Equipment. (Comparison: B01 Sensor )
Size



Main Features of ICC-500T CO₂ controller with S01 sensor

  •  Plug and play, simple operation.
  • Dual relays, are able to connect with the CO₂regulator or generator and the exhaust fan simultaneously.
  • Dual readouts, displays the current measured CO₂ concentration and the set
  • CO₂ concentration simultaneously.
  • CO₂ calibration.
  • Programmable high/low CO₂ concentration alarm.
  • Widely applied in ventilation system, building control and HVAC equipment.

Specification of ICC-500T CO₂ Controller

  • Input Power: 100~240Vac 50/60Hz 10A MAX
  • Output Power: 100~240Vac 50/60Hz 10A MAX
  • (two sockets)
  • Disconnection Method: Type 1B
  • Rated Impulse Voltage: 1500V
  • Automatic Operation: 6000 cycles
  • Ambient temperature:

          Working Environment: room temperature

          Storage Temperature: 0℃~60℃/32℉~140℉

  • Storage Humidity: 20~80%RH (No freezing or condensation)
  • Warranty Period: 2 years
  • Measurement Range: 0~9,999 ppm
  • Sensing Method: NDIR
  • Sensor Working Temperature: 0℃~50℃/32℉~122℉
  • Working Humidity: 0~95%RH (non-condensing)
  • Calibration Method: CO2 reading calibration(current CO2 concentration Value+CO2 calibration value)
  • Error: ± (30 ppm+3% MV)--S01 Sensor
  • Response Time (63%): 20 seconds---S01 Sensor
Plug the CO₂ Controller and the sensor
  • When the CO₂ sensor is inserted, the controller will take about 8 seconds to identify. Then the PV window will display 8888 and blink, the SV window will display the CO₂ concentration setting.
Waiting for about 120 seconds
  • After 120 seconds, CO₂ module works stably, and the PV window stops blinking and displays the measured CO₂ concentration. Within 120 seconds, the buttons cannot be operated , the indicators of WORK1 and WORK2 are off, and the WORK1 and WORK2 have no output.
Plug your devices into the socket of ICC-500T
  • The controller will automatically identify and convert the CO₂ regulator or generator and the exhaust fan. WORK1 is the output of the CO₂ regulator or generator, and the WORK1 indicator is the WORK1 output status indicator. WORK2 is the output of the exhaust fan, and the WORK2 indicator is the WORK2 output status indicator.
  • WORK1 Only for the CO₂ regulator or generator, WORK2 Only for the exhaust fan.
Follow the instructions to finish the setting
  • There are three modes can be set, for more information about setting, please refer to the user manual.

    The Defference between B01 with S01 Sensor

     Multiple uses

    Package Contents

    • ICC-500T*1
    • CO2 S01 Sensor*1
    • User Manual*1
    • Warranty Card*1

    Customer Reviews

    Based on 2 reviews
    100%
    (2)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    B
    Beat Stuber
    CO2

    Nice Product but I miss Wifi. It would be great to have it as well as other inkbird tools

    M
    MARTIN NOURRY

    5 stars, fast shipping and delivering. Had it in the same week from China to Canada.

    X

    Where are we shipping to?

    Enter a message to your customers here